Department of Public Health Dentistry, K.D. Dental College & Hospital Mathura, UP India
INTRODUCTION
Radiology is an important diagnostic aid, essential for accurate and confirmed diagnosis and treatment planning. Radiology imaging being a medical speciality that is used in both diagnose and treat of the diseases, visualized within the human body. Radiologists use an array of imaging technologies such as X-ray radiography, ultrasound, Computed Tomography (CT), nuclear medicine, Positron Emission Tomography (PET) and Magnetic Resonance Imaging (MRI) for the diagnosis or treatment of the diseases.1
X-ray radiography is a tool which uses a beam of X-ray that pass through the concerned body part and carries the information in the resultant transmitted rays visualized on the X-ray films. The low cost factor and simplicity of its use has proved radiography as the most preferred non-invasive diagnostic tools.1
Good quality radiographs are an essential part of dental diagnosis and treatment planning. Dental radiographs are an integral part of everyday clinical dentistry. Dental X-ray equipment are commonly fixed (wall, floor or ceiling mounted) or mobile (tripod mounted on a set of wheels). Traditionally, radiographs have been taken in the dental clinic with a wall mounted intra-oral X-ray unit. Now days, fairly new concept of X-ray unit has came in the market that is the handheld, battery operated, portable machine. Portable X-ray machines are generally much lighter (25 to 50 kg) in weight. They can be easily dismounted and carried in an automobile or on a luggage cart, and they are operated at arm’s length.2,3
Although the first handheld portable dental X-ray devices date back to the early 90s of the past centuries, those devices were intended to be used in the military field. An increase in the marketing of handheld portable X-ray devices for intraoral radiography in general dental facilities has been recently observed.4 They are also used in archaeological excavation sites, humanitarian missions, crime scene/disaster areas for forensic dentistry imaging and veterinary applications.5
Dentists use intra oral as well as the panoramic radiographic aids for the prompt identification of various oral diseases like periapical and periodontal lesions, root caries, cysts, jaw fractures and also to check for the progression and the response to a specific treatment. In the present era, to break the socioeconomic barriers; dental health care facilities should be made available to rural as well as urban sector. Conventional radiography limits their use in remote areas. Fulfilling the need of the health care facilities at community level, there is requirement of availability of such equipments that could easily be transported from one location to another. Portable dental radiographic machines (hand held X- ray machines) will suffice all these requirements and may prove a milestone for community settings.1
Portable radiographic units are small and light weight machines which can be dismantled and carried easily and have a relatively low radiation output. Their design permits easy and simple use and image quality comparable with that of wall mounted conventional radiographic machine. The first portable dental radiographic machine was invented in the year 1921 by a Canadian scientist Frederick Classens. Since then, numerous commercial companies have launched various designs and of those, several have received U.S. Food and Drug Administration (FDA) clearance.1
Types of hand-held x-ray devices4
Types of Portable hand-held X-ray devices
- NOMADTM
- Non-FDA–cleared device
- Tube-based X-ray fluorescence (XRF)
Most accepted and cleared by FDA is NOMAD. NOMAD portable hand-held dental radiation emitting device was developed in 2004 and received FDA approval as a medical device in July, 2005.6
Hand-held X-ray machine offers portability in X-ray technology, featuring cordless operation, rechargeable 14.4V nickel-cadmium battery packs, and provides more than 100–700 exposures on a single charge. It weighs 8 pounds, has internal lead shielding and an external lead–acrylic backscatter shield. There is an automatic shut off and “Enable” feature that minimizes the risk of inadvertent exposure.7
The hand-held X-ray device uses direct current, operates at a fixed 60 kV, 2.3 mA, and has a 0.4 mm focalspot with a 20 cm source-to-skin distance.7
Exposure parameters for hand held X-ray device [Table 1]7
|
Parameter |
Value |
|
Anode voltage |
60 Kv |
|
Anode current |
2.3 Ma |
|
Exposure time range |
0.01–0.99 s |
|
Focal spot size |
0.4 mm |
|
Minimum inherent filtration Al equivalent |
1.5 mm |
|
Source of skin distance |
20 cm |
|
X-ray field |
60 mm round |
|
Clinical exposure times: PSP |
|
|
Anterior PA |
0.16 s |
|
Posterior PA Bitewing |
0.19 s |
|
Bitewing |
0.20 s |
|
Maximum duty cycle |
1:60 s |
|
Current used |
DC |
|
Total weight |
<4kg |
Whole body radiation exposure limit for hand held X-ray device [Table 2]7
|
Recommendation for Dose Limit |
Occupational Dose Limit |
|
50 mSv |
Occupational allowance |
|
3.65 mSv |
Yearly background exposure from normal activities |
|
0.65 mSv |
Yearly exposure using NOMAD with D-speed film |
|
0.26 mSv |
Yearly exposure using NOMAD with a digital sensor |
The high-voltage power supply is a high-frequency DC unit, which reduces the dose to the patient. Second, the X-ray tube is surrounded by compounds of heavy metals to reduce the leakage radiation from the tube.7
The current hand-held portable X-ray devices resemble a photographic camera or have a “shotgun” design. The devices are used as a replacement for wall-mounted or semi mobile X-ray devices (on a tripod or mobile support) and differ in two major characteristics from wall mounted X-ray devices:
- The operator holds the hand‑held portable X-ray devices during exposure of the patient, so the operator can not stand back of radiation protection shields and therefore, dedicated means of (scatter) radiation protection need to be provided.
- The newer handheld devices typically have a lower output dose rate (set by current, wave form, filtration and cone length) than the traditional wall-mounted direct current units.7
The main concern with handheld portable X-ray units is unnecessary exposure to radiation and the dose to the operator. The mode of use of portable X- ray machine has raised a number of questions over possible radiation safety issues affecting the operator.5 The international guidelines on radiation protection define a distance of at least 2 m from the X-ray tube by the operators for stationary tubes.8 Maintaining a safe distance outside the “controlled zone” and not holding the X-ray equipment are universally recommended while using fixed or mobile X-ray units to avoid exposure from radiation leakage from the X-ray tube head and from backscatter. The “controlled area” is a zone 1.5 m in any direction from the patient and X-ray tube head and anywhere in the line of the main X-ray beam. Handheld portable X-ray units challenge the concept of a restricted access to the “controlled area” as they are held by the operator. To overcome this problem manufacturers have included a lead shield within the handheld portable X-ray unit. In addition, there is a lead-embedded acrylic protective shield at the end of the X-ray tube head to create a protective zone against backscatter.5 When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.9
INDICATIONS FOR THE USE OF HANDHELD PORTABLE DENTAL X-RAY DEVICE 10
The use of handheld portable X-ray devices can be divided into patient-related situations and forensic situations.
Use in intraoral dental radiography of patients
As a general rule, a handheld portable X-ray device should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed mounted or semi-mobile X-ray device is proven impractical such as in:
i. Operation theatres where no fixed mounted X-ray unit is available and the patient is under general anaesthesia or sedation.
ii. Emergency rooms, surgical suites, patient rooms or other hospital facilities for immobile patients.
iii. Nursing homes, residential care facilities or homes for persons with disabilities, which compromise mobility or their general health and who are thus unable to attend a healthcare facility. In this case, the follow-up treatment should be considered before justification of the X-ray procedure is made. If follow-up treatment is not available at the site, the patient might need to be moved to a healthcare facility and X-ray imaging can be performed at the healthcare facility.
iv. Detention centre facilities where persons are physically confined and cannot easily be moved or transferred.
v. Work in remote areas without dental facilities such as military operations abroad.
vi. Dental support in rural areas in developing countries or isolated areas without dental facilities.
Use in forensic odontology
Handheld portable X-ray devices may be used in applications of forensic odontology for example in mass disasters or fatal accidents, where a multitude of individuals have to be identified on site or in facilities lacking fixed mounted units. Also, the electricity supply might be cumbersome or even absent in mass disaster areas or fixed X-ray units may get damaged by constant line fluctuation. In those circumstances, a handheld portable X-ray device may be of benefit for the identification process.
ADVANTAGES OF HAND-HELD RADIOGRAPHY FOR DENTAL PROFESSIONALS 4
• Operator can stay with the patient during X-ray procedures.
• Take radiographs twice as fast as with conventional X-ray systems.
• Reduce number of retakes by up to 50%.
• Move hand-held X-ray devices from room to room, eliminating the need for multiple units.
• Carry anywhere – ideal for hospital, home-health, humanitarian, and out-of-office use.
• The any high degree of flexibility makes it easy to take exposures while the patient is reclined, lying completely on their back or sitting upright.
• There are less chances of cone-cut and others errors in taking X-rays.
• No need to follow accurate angulations. Usually 90° or perpendicular to the film or sensor is maintained.
• Light weight, cordless, easily transportable.
• No awkward arms to manipulate; no drift.
• No need for special stands, cables, remotes & hundreds of diagnostic quality images from a single battery charge.
• Works with sensors, film, phosphor plates.
• Exceptionally valuable in dental surgery suites.
• Perfect for use with sedated patients, children, geriatric or special needs.
• Ideal for general dentistry, humanitarian work, clinics, mobile, home health, hospitals.
• It is rechargeable one so no need of current to operate the device.
DISADVANTAGES OF HAND‑HELD RADIOGRAPHY FOR DENTAL PROFESSIONALS 4
• The main drawback is that ALARA principal is not followed.
• The device must be angled and the operator cannot be completely within the protection zone.
• Compulsory lead apron is necessarily should be worn by the operator.
• Some time the radio-frequency which is used to produce X-ray leads disturbs other operating machines.
• An experienced operator is needed.
CONCLUSION
Portable radiographic machines may prove a landmark in community settings to serve the underserved. They have a comparable image quality as that of conventional wall mounted machines. With their compact and simple design; their feasibility in community dental set up is much advocated. A proper understanding with increased availability of these equipments will thus help us achieve HEALTH FOR ALL. At present, it is very difficult to comment on their use for the mass. But still, looking into their technical considerations and their image quality, their future looks promising in the field of dental public health.
REFERENCES
- Swati J, P Basavaraj, Sowmya AR. Portable dental radiographic machines- A systematic review. J oralfacial and health sci. 2013; 4(2).
- U Jogezai T Riches, D Townsend and C Abercrombie. Introduction of a Nomad Pro hand held dental x-ray unit for radiography in a special care setting. Journal of Disability and Oral Health. 2016;17(2):78-84.
- https://www.inesss.qc.ca/fileadmin/doc/AETMIS/Rapports/AidesTechniques/2002. Accessed on 25/12/2020.
- Gargi Patil , Vishwas Kadam , Lata Kale , Sonia Sodhi. A Paradigm Shift from Mounted Intra-Oral Periapical Radiography to Hand-Held X-Ray Device: A Review. Annals Inter Medic & Dent Rese. 2019; 5(6):25-27.
- Jimmy Makdissi, Ravikiran R Pawar, Ben Johnson and Bun S Chong. The effects of device position on the operator’s radiation dose when using a handheld portable X-ray device. Dentomaxillofac Radio .2016; 45(1):1-7.
- Robert A. Danforth, Edward E. Herschaft, and John A. Leonowich. Operator Exposure to Scatter Radiation from a Portable Hand-held Dental Radiation Emitting Device (AribexTM NOMADTM) While Making 915 Intraoral Dental Radiographs. J Forensic Sci. 2009;54(2):415-421.
- V Ramesh DN, Wale M, Thriveni R, Byatnal A. Hand‑held X‑ray device: A review. J Indian Acad Oral Med Radiol. 2018;30:153‑7.
- S M Hosseini Pooya, L Hafezi, F Manafi and A R Talaeipour. Assessment of the radiological safety of a Genoray portable dental X-ray unit. Dentomaxillofac Radio.2015; 44(1), 2-4.
- Jeong-Yeon Cho, WonJeong Han. The reduction methods of operator’s radiation dose for portable dental X-ray machines. Restor Dent Endod. 2012;37(3):160-164.
- Berkhout WER, Suomalainen A, Brullmann D, Jacobs R, Horner K, Stamatakis HC. Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of Dento Maxillo Facial Radiology (EADMFR). Dentomaxillofac Radiol. 2015; 44 (1): 2-6.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Saumya Jaiswal, Dr. Navpreet Kaur, Dr. Roopali Gupta. Portable Dental Radiographic Machine. Guident. 2020 Dec;14(1). Available from: https://guident.net/articles/general/portable-dental-radiographic-machine.html