Prosthetic Rehabilitation of a Complete Bilateral Maxillectomy Patient Using a Two-Piece Magnetically Connected Prosthesis with Hollow Obturator: A Case Report
Department of Prosthodontics, Pt. B.D Sharma University of Health Sciences, Rohtak, India
ABSTRACT
A complete bilateral maxillectomy defect results in devastating effects on cosmetics, functional and psychological aspects of the patient. The prosthetic treatment objectives are to separate the nasal and oral cavities, restore the mid-facial contour, and improve the masticatory functions by providing a full complement of maxillary teeth. Insertion and removal of a large prosthesis used for rehabilitation of midfacial defects require good neuromotor coordination and adequate mouth opening. This case report describes the fabrication of a two-piece magnetically connected prosthesis with a hollow obturator which not only restores the patient’s masticatory efficiency and swallowing but as well improves the speech and psychological aspect of the patient.
KEYWORDS: Bilateral complete maxillectomy, Hollow obturator, Magnets, Two-piece prosthesis.
INTRODUCTION
Maxillofacial prosthodontics is the field of prosthodontics that deals with the restoration and/or replacement of stomatognathic and craniofacial structures with a prosthesis that may or may not be removed on a regular or elective basis. The goal of maxillofacial prosthetics is to restore function and aesthetics. Few of the maxillary defects may result as sequelae of the surgical treatment of neoplasm.1 Extensive bilateral midfacial defects involving the upper jaw, palate, and sinus present a formidable reconstructive challenge.2 Bilateral complete maxillectomy is a relatively uncommon surgical procedure resulting in devastating effects on the cosmetics, functional and psychological aspects of a patient’s life.
A patient with an acquired maxillary defect should be provided with the best care possible, an obturator that is comfortable, restores speech and mastication. and has acceptable aesthetics. When working with a patient who has a maxillary deformity, the clinician may need to deviate from some of the basic principles of prosthesis design. Patients with a large defect can have difficulty in inserting the large obturator through the small oral opening.3 The prosthesis can be separated into two or more components, if necessary. The function and ease of insertion and removal of a large prosthesis must be addressed while constructing a sectional prosthesis.
Magnets have wide application in prosthetic dentistry. The employment of magnets in overdenture retention overcomes the issue of readjustment and wear, as well as the need for specific equipment and advanced laboratory procedures that are required with traditional attachment systems. Also, the buccal and lingual sections of the sectional prosthesis can be joined together by using a magnetic assembly. They are also employed in implant-supported overdentures and for stabilization, retention, and maintenance of a combined maxillofacial prosthesis.
Magnets are a common retention approach because of their tiny size and high attraction forces, they may be incorporated into a prosthesis without being obtrusive in the mouth. Both attractive and repulsive forces have been used in the field of prosthetic dentistry. Magnetic repulsion has been used to limit the displacement of dentures by the incorporation of magnets into the posterior segments of the dentures with like poles in apposition.
This case report describes the prosthodontic rehabilitation of a patient following bilateral full maxillectomy using a closed hollow obturator attached to the separate teeth-bearing denture section via magnets.
CASE REPORT
Diagnosis
A 35-year-old man reported to the Department of Prosthodontics with a chief complaint of missing teeth in the upper jaw. His primary concerns were the inability to chew food, and regurgitation of the food into the nasal cavity. He also had complaints of resonance of his sound and speech problems with restricted mouth opening. The patient had a history of diabetes and was on medication for the past 3 years. He was diagnosed with mucormycosis infection as a complication of dental extraction, for which a bilateral complete maxillectomy was done followed by post-surgical radiation therapy. The extra-oral examination revealed a collapsed midface (Figure 1). Intra-oral examination revealed complete resection of the maxilla (Figure 2).
Figure 2 (A to B): A. Intra-oral view showing bilateral maxillectomy; B. Orthopantomagram showing the resected maxilla..
Treatment Plan
The various prosthetic treatment goals were to restore esthetics by contouring the mid-face, improving the speech and mastication by providing the denture, and separating the oral and nasal cavities to prevent the regurgitation of food and resonance of the sound. Various treatment alternatives like implant-retained prosthesis, circumzygomatic wiring were suggested to the patient but the patient was willing for a more conservative treatment. So, a two-piece hollow obturator denture prosthesis attached by magnets was designed and constructed to achieve these goals.
Fabrication of Prosthesis
Irreversible hydrocolloid impression material was used to make the primary impressions of the maxillary and mandibular arch (Figure 3). The impressions were poured to obtain the primary casts. The primary maxillary cast was outlined to fabricate a special tray using auto-polymerizing acrylic resin. Border moulding of a special tray was done with a green stick compound to record the functional anatomy of the buccal and labial soft tissue surrounding the defect. To make the final impression, the gross extent of the defect was recorded by using putty consistency addition silicone impression material. The final wash impression was made using light body addition silicone material (Figure 4).
Two master casts (one split and one intact) were obtained from this impression. Laboratory verification of the fit of the obturator was done using the split cast and wax-up (Figure 5) and flasking was done using the intact cast. Undercuts were blocked with wax on the intact master cast and the remaining portion of the defect was waxed to a minimum thickness of 3mm to provide an adequate thickness of heat-cured acrylic resin obturator. Following deflasking, a finished and polished obturator was obtained. Try-in of the obturator (Figure 6) was done to evaluate the fit and speech.
After the try-in, palatal contouring of the obturator was done to simulate the anatomy of the maxillary ridge using modelling wax and was cured using heat-cured acrylic resin by the lost salt technique (Figure 7) to make it hollow so that the denture retention is not compromised due to the weight of the prosthesis. A final impression (Figure 8A) of the palatal surface was then made using light body addition silicone impression material with the custom tray fabricated on primary casts. The resultant impression was poured to obtain the master casts. A permanent denture base was fabricated on the master cast (Figure 8B) and magnetic assembly was given to both the permanent denture base resin and the obturator. Neodymium magnets (N52, 12x4mm) were placed, two at the canine region on both sides and one on the posterior mid palatal region (Figure 9) to create a means for the denture portion of the prosthesis to attach to the obturator portion of the final prosthesis.
Figure 7 (A to B): A. Fabrication of hollow obturator using the lost salt technique; B. Try-in of the hollow obturator.
Figure 8 (A to B): A. The final impression of the palatal surface of the hollow obturator; B. Permanent denture base on the master cast.
Figure 9: Magnetic assembly given to both the permanent denture base resin and the obturator placed at the canine region on both sides and one on the posterior mid palatal region.
The obturator portion of the prosthesis was inserted into the defect to determine jaw relations. The denture portion was attached to the obturator by means of the magnetic assembly and the jaw relations were recorded (Figure 10A). The casts were then mounted on a mean value articulator and the teeth arrangement was done (Figure 10B). Wax-up of the palatal region was done with care to ensure that palatolingual and linguodental associated consonants can be properly pronounced. Following the try-in and final approval of the patient, the denture was processed, finished, and polished (Figure 11A).
Figure 10 (A to B): A. Recording the jaw relation using magnetic assembly; B. Try-in of denture portion of the prosthesis.
Figure 11 (A to B): A. Final two-part prosthesis with magnetic assembly; B. Insertion of the final two-part prosthesis.
The finished and polished prosthesis was inserted into the patient’s mouth (Figure 11B) to assess the fit between the two portions of the prosthesis. Soft tissue relining material was applied on the tissue surface and instructions for insertion, removal, and maintenance of the obturator were given. Speech, masticatory efficiency, and swallowing improved considerably following insertion of the prosthesis. Follow-up was done at regular intervals.
DISCUSSION
Rehabilitation of a complete maxillectomy defect is challenging due to the issues with speech, deglutition, and aesthetics. For patients with such large defects, the basic goals of prosthodontic therapy should include tissue preservation, positive support, retention, and stability of the prosthesis.4,5,6 Reducing the weight of the prosthesis significantly improves the retention and stability of the obturator. The cantilever mechanics of suspension are improved by lightening the obturator part, which prevents overtaxing the remaining supportive components and enhances retention. It also provides resonance to the speech by simulating the functional architecture of the maxillary sinus.
In the literature, there are a few surgical and prosthetic options to rehabilitate individuals with bilateral maxillectomy defect. For patients with bilateral maxillectomy, implants-supported prostheses, Steinmann pins and magnets, and circumzygomatic wiring have been utilized and described. However, the generalized debilitations of systemic health in patients as a result of surgery, radiation, and chemotherapy, as well as financial considerations, have tainted their usefulness. The use of two parts of an obturator aligned by magnets to assist simple insertion and removal of the prosthesis from the locking effect of the soft tissue undercuts of a surgical defect has been documented in a sectional prosthesis.7 However, this design poses a dilemma for geriatric individuals and those with impaired motor abilities.
The prosthesis described in this article, on the other hand, has numerous advantages, including ease of insertion for both the patient and the dentist, consistent retention, and stability in terms of avoiding prosthesis movement to minimize undue stress on the underlying soft tissues of the defect. In the literature, a hollow silicone obturator with an acrylic palatal part has been reported.8 However, the use of this type of prosthesis is limited due to the difficulties of inserting and removing a single large prosthesis in patients with a limited mouth opening. The treatment strategy was modified to fabricate a two-piece magnetically attached prosthesis as a result of these factors.
Magnets have a good locking potential and give persistent retentive properties once in position. The size and diameter of the magnet may be adjusted to fit the size of the defect and prosthesis. Microvascular surgical procedures have transformed surgical reconstruction, yet prosthetic rehabilitation remains necessary. Silicone rubber and light polymerizing acrylic resin lack strength leaving the long-term durability of these materials in question. On the other hand, heat polymerizing acrylic resin has been proven to be one of the most durable tissue-compatible materials to date. The disadvantage of these heat-cured prostheses is that they require a few additional laboratory steps to fabricate them.
When compared to open field magnetic systems, the closed field magnetic system employed in this prosthesis lowers the magnetic field influence in the oral cavity. It also reduces the cytotoxicity of corrosion products generated by magnets. Fabrication of the obturators has been done using several materials. The long-term endurance of silicone rubber and light polymerizing acrylic resin is under doubt due to their lack of strength. Heat polymerizing acrylic resin, on the other hand, has been shown to be one of the most lasting tissue-compatible materials to date. The downside of the heat-cured prosthesis is that they need a few more laboratory processes to manufacture.
CONCLUSION
The controversy about the prosthetic and surgical reconstruction of the maxillary defects persists. A simple obturator can be used to reconstruct the majority of maxillary deformities. The insertion and removal of a large prosthesis used to treat midfacial abnormalities, on the other hand, need strong neuromotor coordination and a sufficient mouth opening. A two-piece magnetically linked prosthesis was created to overcome these difficulties faced by the patient. Following insertion not only did the speech, masticatory efficiency, and swallowing improved considerably but it also led to an increase in the confidence of the patient to lead a normal social life.
REFERENCES
- Aramany MA. A history of prosthetic management of cleft palate: pare to Suersen. Cleft Palate J 1971;8:415.
- Panje WR, Hetherington HE, Toljanic J, Fyler A. Bilateral maxillectomy and mid facial reconstruction.Ann Otol Rhinol Laryngol. 1995; 104;845-9.
- Desjardins RP. Obturator prosthesis design for acquired maxillary defects.J Prosthet Dent 1978;39:424-35.
- Devan MM. The nature of the partial denture foundation, suggestions for its preservation. J ProsthetDent. 1952; 2:210-16.
- Des Jardins RP. Obturator prosthesis design for acquired maxillary defects. Prosthet Dent. 1978;39:424-35.
- Brown KE. Clinical considerations in improving obturator treatment. J Prosthet Dent. 1970;24:461-66.
- Wang RR. Sectional prosthesis for total maxillectomy patient. J Prosthet Dent. 1997; 78:241-4.
- Wood RH, Carl W. Hollow silicone obturator for patients after total maxillectomy. J Prosthet Dent.1977; 38:643-51.
Disclaimer from Guident
The views and opinions expressed in articles published in Guident are solely those of the authors and do not necessarily reflect the views of the editors, the editorial board or the publisher, Ivory India. Guident does not endorse any product, technique or treatment described. Clinical content is intended for qualified dental and medical professionals and is not a substitute for individual clinical judgement. Guident, its editors and the publisher accept no liability for any consequence arising from the use of information published in the journal.
How to cite this article
Dr. Aman Duhan, Dr. Divya Dahiya, Dr. Sujata Chahal. Prosthetic Rehabilitation of a Complete Bilateral Maxillectomy Patient Using a Two-Piece Magnetically Connected Prosthesis with Hollow Obturator: A Case Report. Guident. 2021 Sep;14(10). Available from: https://guident.net/articles/prosthodontics/prosthetic-rehabilitation-of-a-complete-bilateral-maxillectomy-patient-using-a-two-piece-magnetically.html